Part Number Hot Search : 
150L40AM 2SC2130 BT2222 MC4013 04110 SI4666DY APW7281 FR3SMBA
Product Description
Full Text Search
 

To Download UFE1300-5 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  313 process yellow 3405 1797 1375 116 2607 652 242 2985 375 240 embedded power for business-critical continuity ufe / ufr series up to 6000 watts special features ? rack mounted chassis (1u, 19) ? 3 hot pluggable rectifers per 1u chassis, up to 4 kw redundant or 6 kw available power (180-264 vac input) ? up to 2.6 kw redundant or 3.9 kw available per shelf at 90-132 vac input ? stackable to 6u high to provide up to 36 kw available power ? class b conducted emi en55022 (see note 1) ? automatic fan speed control with fault reporting ? auxiliary standby output, 11 v at approximately 2.8 w ? high density up to 22 w/in3 ? high effciency up to 91% ? floating as well as isolated main output voltage allows positive or negative polarity operation ? eu directive 2002/95/ec compliant for rohs ? 2 year warranty ? pmbus compliant total power: up to 6000 w input voltage: 85 - 264 vac # of outputs: single + aux output: 24 v & 48 v safety vde en/iec60950-1 ul/cul60950-1 ? ? rev.8.26.09_154 ufe / ufr series 1 of 6 electrical specifcations all specifcations are typical at nominal input, full load at 25 o c ambient unless otherwise stated. output output power: main output auxiliary output see table 1 11 v 15%, 2.875 w line regulation: low line to high line 0.15% max. load regulation (active share mode): full load to min. load 0.15% max. turn-on delay: (see note 4) 5.0 s max. ambient temp. coeffcient: at full load, min. vin 0.005%/oc voltage adjustability: adjustable pmbus command (see note 6) 48 vout 24 vout 42-57 vdc 21-28.5 vdc output setpoint accuracy: 0.5% default output voltage: setting 25 oc 48 vout (active default) 24 vout (active default) 48 v 0.5% @ 41 a 27 v 0.5% @ 48 a voltage droop: (operation set pmbus command) 24 vout 48 vout 40.3 mv/a 3.0% from 10 a up to power limit 80.6 mv/a 3.0% from 10 a up to power limit total error band: -40 oc to +70 oc, fl range 1.0% max. overshoot/undershoot: main output @ turn-on/off 0%/0% ripple and noise (20 mhz): main output, -5 oc and above auxiliary output 500 mv pk-pk, 150 mv rms 400 mv pk-pk, 150 mv rms dynamic regulation (except droop mode): peak dev., 25% load step recovery time 2.5% max. 1 ms max. current sharing (see note 3): (i1-i2) / ilimit x 100 15% max.
rev.8.26.09_154 ufe / ufr series 2 of 6 embedded power for business-critical continuity 313 process yellow 3405 1797 1375 116 2607 652 242 2985 375 240 notes 1 final emi performance is system/shelf dependent. 2 auto ranging sets power limit based on input voltage at turn on. 3 the difference in output current among any two rectifers operating in parallel does not exceed a value equal to 15% of the rated current limit. this specifcation applies for operation with any output current from no load to 110% of maximum. 4 maximum 15 minute warm up time at light loads below -15?c. see application note 212 for cold start timing data. 5 for operation above 1,524 m (5,000 ft), maximum operation temperature is derated by 2 oc per 305 m (1,000 ft). 6 output voltage can be modifed on the fy between 21-28.5 v (24 v model) or 42-57 v (48 v model) pmbus command. 7 pm bus communication. pin names in parenthesis refer to the pmbus version names. ufe2000-96s48pj and ufe130096s24pj use pmbus. input input voltage range: (see note 2) 88-264 vac 176-264 vac input frequency range: 47-63 hz input current: 15 a max. ground leakage current: ac to safety ground 2 ma max. input fuse (internal) both lines fused 30 a power factor: 50 to 100% load 0.98 undervoltage lockout: (power up) high line range wide line range 176 vac max. 88 vac. max undervoltage lockout: (power down) high line range 162 vac min. led warning @ 176 v max. wide line range 76 vac min. led warning @ 88 v max. general specifcations electrical insulation: input/output input/chassis 3000 vac / 4242 vdc 1500 vac / 2121 vdc switching frequency: fixed 450 khz approvals and standards: vde en/iec60950-1 ul/cul60950-1 weight: 5.5 lbs hold-up time: 48 vout at rated output power 24 vout at rated output power 20 ms min. 20 ms min. mtbf (@25 o c): telcordia sr-332 issue 1 279,069 hours acoustical noise: over all conditions 25 o c ambient at rated output power 71 db max. 58 db typ. emc conducted emissions: en55022, fcc part 15 class b (when installed in system) immunity: harmonic current: en61000-3-2 compliant esd air/contact: en61000-4-2 level 3 surge: en61000-4-5 fast transients: en61000-4-4 level 3 flicker: en61000-3-3 compliant magnetic feld: en61000-4-8 compliant radiated immunity: en61000-4-3 level 3 conducted immunity: en61000-4-6 level 3 ordering information rated output power output voltage vout output current (min) power limit +15% / -0% vout (min) line range at turn on (auto ranging) operating line range current limit (vout) < vout (min) m odel num?ers odel num ?ers (7) orde r num?er num ?er min max 24 vout models 1300 w 21 v 28.5 v 0 a 1300 w 90-264 vac 65 a 65 a ufe1300-96s24pj UFE1300-5 48 vout models 1300 w 42 v 57 v 0 a 1300 w 90-264 vac 33 a 33 a ufe2000-96s48pj ufe2000-9 2000 w 42 v 57 v 0 a 2000 w 180-264 vac 52 a 52 a 1300 w 42 v 57 v 0 a 1300 w 90-264 vac 33 a 33 a ufe2000-96s48pdj ufe2000-9-d 2000 w 42 v 57 v 0 a 2000 w 180-264 vac 52 a 52 a 1300 w 42 v 57 v 0 a 1300 w 90-264 vac 33 a 33 a ufe2000-96s48phdj ufe2000-9-hd 2000 w 42 v 57 v 0 a 2000 w 180-264 vac 52 a 52 a rack ordering information rack model num ?er hot plug interface num? er of power modules per pack ufr6000-00j yes 3 ufr6000pj blank panel 3
rev.8.26.09_154 ufe / ufr series  of 6 embedded power for business-critical continuity 313 process yellow 3405 1797 1375 116 2607 652 242 2985 375 240 product family ufe ufe = universal front-end input range 9 = universal input with pfc standard compliance 6 6 = ul/csa/vde class a/b rated output power 2000 1300 = 1300 watts 2000 = 2000 watts output voltage 48 48 = 48 v 24 = 24 v type of output s s = single communications type c p = pmbus serial communications special modification option code none = active ishare d = droop ishare hd = ps enable hi/droop rohs compliance (9) j j = pb free (rohs 6/6 compliant) ufe 2000 9 6 s 48 p d xx j environmental specifcations thermal performance: (see notes 4 and derating curves) operating non-operating cold start -33 c to +70 c -40 c to +100 c -40 c relative humidity: non-condensing operating non-operating up to 80% up to 95% altitude: (see note 5) operating non-operating 10,000 feet max. 35,000 feet max. vibration: operating non-operating 1.0 g peak 1.5 g peak shock: operating non-operating 10 g peak / 11 ms ms 40 g peak / 11 ms protection power limit: vo > vout min rated power +15%/-0% current limit: constant current limiting - brickwall vo 2 vout min limit, 8% short-circuit: hiccup mode at vo < 40 vdc vo < 20 vdc 200 ms on / 1/8 s off overvoltage: output shutdown latching after 1 retry 60 v max. 32 v max. thermal: self protecting non-latching or-ing fault (see note 7) tested via i 2 c or pmbus led alarm (by read) in case of or-ing fault communication monitoring readout accuracy current: valid from 15% to max. load 15% voltage: measured before output or-ing 5% temperature: measured internal output or-ing 5 c c hours counter: 36 s/hours approx. part number system with options
embedded power for business-critical continuity 313 process yellow 3405 1797 1375 116 2607 652 242 2985 375 240 5.56 0.03 (141.2 0.8) 1.60 0.02 (40.6 0.5) 9.58 0.02 (243.3 0.5) with pem scre w fastened 10.74 0.02 (272.8 0.5) front face to connector 11.95 0.03 (303.5 0.8) dim en sions in inches (mm ) 0.17 0.01 (4.3 0.3) 5.51 0.02 (140.0 0.5) d c b a powe r power signal p1 p2 p3 p4 p5 p6 p7 1 2 5 3 6 4 power connections layout (looking into connector side of ufe power supply) mechanical drawing power supply connector mating connector molex: 87663-4006 molex: 87664-2004 tyco: 2-1450330-8 tyco: 1450370-5 fci berg: 51939-180 fci berg: 51915-070 power supply connector power supply connector pinout pin d c b a p1 l1 p2 l2 p3 peg 1 sense- sense+ gnd shortpin 2 present-l gnd ps-id0 gnd 3 ps-id3 ps-id2 gnd 12v-aux 4 gnd scl ps-id1 gnd 5 sda gnd gnd i 2 c-en-h (comm-en-h) 6 smbalert# ishare dc-ok-l ps-en (control) p4 dc_n p5 dc_n p6 dc_p p7 dc_p rev.8.26.09_154 ufe / ufr series 4 of 6
rev.8.26.09_154 ufe / ufr series 5 of 6 embedded power for business-critical continuity 313 process yellow 3405 1797 1375 116 2607 652 242 2985 375 240 .256 .015 1.740 .015 11.777 .015 10.326 .015 .125 .010 r.125 .015 1.250 .010 .220 .010 18.435 .010 18.880 .015 17.312 .015 15.259 .015 15.000 .015 14.559 .015 14.972 .010 1.740 .015 rack specifcations rack signal connector pinout pin no. function pin no. function 1 sense+ 14 ishare 2 ground 15 unit 1 present 3 sense- 16 ground 4 ground 17 unit 2 present 5 ps-en (control) 18 ground 6 dc1-ok0-l 19 unit 3 present 7 dc2-ok-l 20 ground 8 dc3-ok-l 21 scl 9 i 2 c-en-h-1 (comm-en-h) 22 ground 10 i 2 c-en-h-2 (comm-en-h) 23 sda 11 i 2 c-en-h-3 (comm-en-h) 24 ground 12 ground 25 smbalert# 13 12v-aux 26 n/c signal connector (1 per shelf) shelf connector mating connector molex: 52986-2679 molex: 52316-2619 tyco: 2-178238-4 tyco: 2-5175677-4 ac input connector (3 per shelf) shelf connector mating connector iec320 c20 socket iec320 c20 plug (straight entry) shelf dip switch table shelf number dip switch dip switch 1 up up 2 up down 3 down up 4 down down
313 process yellow 3405 1797 1375 116 2607 652 242 2985 375 240 embedded power for business-critical continuity rev.8.26.09_154 ufe / ufr series 6 of 6 output power (w ) ambient tempera ture ( oc ) b a o output power (w) ambient tempera ture (oc) a power ra ting (w ) ambient tempera ture (oc) figure 1 - thermal derating curve for ufe2000-96s48j model low line input voltage figure 2 - thermal derating curve for ufe2000-96s48j model high line input voltage figure 3 - thermal derating curve for ufe1300-96s24j model all conditions americas 5810 van allen way carlsbad, ca 92008 usa telephone: +1 760 930 4600 facsimile: +1 760 930 0698 europe (uk) waterfront business park merry hill, dudley west midlands, dy5 1lx united kingdom telephone: +44 (0) 1384 842 211 facsimile: +44 (0) 1384 843 355 asia (hk) 14/f, lu plaza 2 wing yip street kwun tong, kowloon hong kong telephone: +852 2176 3333 facsimile: +852 2176 3888 for global contact, visit: www.powerconversion.com techsupport.em?eddedpower @emerson.com while every precaution has been taken to ensure accuracy and completeness in this literature, emerson network power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. emerson network power and the emerson network power logo are trademarks and service marks of emerson electric co. ?2009 emerson electric co. emersonnetworkpower.com embedded computing em? edded power monitoring outside plant power switching & controls precision cooling racks & integrated cabinets services surge protection emerson network power. the global leader in enabling business-critical continuity. ac power connectivity dc power


▲Up To Search▲   

 
Price & Availability of UFE1300-5

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X